123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081 |
- Gluon 2017.1.2 (in development)
- ===============================
- New features
- ~~~~~~~~~~~~
- * Preserve *gw_mode* on sysupgrades (`#1196 <https://github.com/freifunk-gluon/gluon/issues/1196>`_)
- When a Gluon node is used as uplink (for example by connecting it to a router with
- a DHCP server directly, instead of using non-Gluon servers for the internet uplink),
- the *gw_mode* must be set to *server* on that node. The changed *gw_mode* is now
- preserved on upgrades.
- * Allow configuring the batman-adv routing algorithm (*BATMAN IV* or *BATMAN V*)
- in *site.conf* (`#1185 <https://github.com/freifunk-gluon/gluon/issues/1185>`_)
- *BATMAN V* still hasn't received extensive testing (and is incompatible with *BATMAN IV*).
- This new option allows to set up *BATMAN V*-based test meshes. If unset, the routing
- algorithm will default to *BATMAN IV*.
- Configuration:
- .. code-block:: lua
- mesh = {
- batman_adv = {
- routing_algo = 'BATMAN_V'
- }
- }
- * New *show-release* Make target
- The command ``make show-release`` can be used to print the release number
- defined by *GLUON_RELEASE* to the standard output. This can be useful for build scripts
- when a ``$(shell ...)`` expression is used in *site.mk* to generate the release
- number.
- Bugfixes
- ~~~~~~~~
- * The image build code used for some devices has been fixed, solving multiple
- issues (`#1193 <https://github.com/freifunk-gluon/gluon/issues/1193>`_)
- Problems caused by this issue include:
- - sysupgrade rejecting Allnet images
- - OpenMesh devices losing their configuration on upgrades
- This is a regression in Gluon v2017.1.
- * Improve sysupgrade error handling (`#1160 <https://github.com/freifunk-gluon/gluon/issues/1160>`_)
- If for some reason processes don't react to SIGKILL (usually because of a kernel bug),
- a node could hang forever in sysupgrade, requiring a power cycle. This has been
- fixed, triggering a reboot instead.
- * Also display *gluon-config-mode:novpn* message when Tunneldigger is installed, but disabled
- (`#1172 <https://github.com/freifunk-gluon/gluon/issues/1172>`_)
- It was only displayed on nodes with fastd before.
- Known issues
- ~~~~~~~~~~~~
- * Default TX power on many Ubiquiti devices is too high, correct offsets are unknown (`#94 <https://github.com/freifunk-gluon/gluon/issues/94>`_)
- Reducing the TX power in the Advanced Settings is recommended.
- * The MAC address of the WAN interface is modified even when Mesh-on-WAN is disabled (`#496 <https://github.com/freifunk-gluon/gluon/issues/496>`_)
- This may lead to issues in environments where a fixed MAC address is expected (like VMware when promicious mode is disallowed).
- * Inconsistent respondd API (`#522 <https://github.com/freifunk-gluon/gluon/issues/522>`_)
- The current API is inconsistent and will be replaced eventually. The old API will still be supported for a while.
- * Sporadic segfaults of busybox (ash) when running shell scripts on ar71xx
- (`#1157 <https://github.com/freifunk-gluon/gluon/issues/1157>`_)
- The workaround added in Gluon v2017.1.1 has greatly reduced the frequency of
- segfaults, but did not make them disappear completely.
|